Normal Procedure Checklists

 

 

Preflight Check

 

Parking Brake   

  SET

All Light Switches    

  OFF

Deice Switches   

  OFF

All Circuit Breakers    

  IN

Doors   

  CLOSED

 

Before Starting Engine

 

Preflight Inspection and check   

  COMPLETE

Cabin Doors   

  LATCHED

Parking Brakes   

  SET

All Light Switches   

  OFF

Deice Switches   

  OFF

Essential Avionics   

  OFF

Nonessential Avionics   

  OFF

IEC / TTL Computers   

  OFF

Generator 1 and 2   

  OFF

Ignitions   

  NORMAL

AC Transfer Switch   

  NORMAL

Electric Master Emergency Switch   

  NORMAL

Engine Firewall Levers   

  OFF

Power Lever   

  IDLE

Fuel Condition Lever   

  CUTOFF

Fuel Crossfeed   

  SHUT

Fuel Quantity   

  CHECK

Oil Cooling Flaps   

  AUTO

Prop Synchro   

  OFF

Annunciator Lights   

  PRESS TO TEST

Annunciator Day/Night Switch   

  SET

Battery Switch   

  ON

Voltmeter Mode Switch   

  BATTERY VOLTS

Essential Avionics   

  ON

 

Starting Engine with Automatic Starters (Battery Start)

 

Battery Switch   

  ON

Fasten Seat Belts Switch   

  ON

Voltmeter   

  CHECK (24 Volts Minimum)

Propeller Area   

  CLEAR

Air/Ground Switch   

  SET

Left Generator   

  RESET

Both Generators   

  OFF

Ignitions   

  NORMAL

IEC Computers   

  ON

IEC Annunciator Light   

  ON

Low Pressure Fuel Valve   

  OPEN

Left Boost Pump   

  ON

Left Fuel Condition Lever   

  TAXI

Left Fuel Pressure   

  CHECK (15 PSI Minimum)

Left Fuel Pressure Warning Light   

  OFF

Left Engine Selector   

  ON

Left Engine Starter   

  ON

Left Engine Oil Pressure   

  CHECKED FOR INDICATION

Left NG   

  STABLE (12% Minimum)

Left Fuel Flow   

  CHECK

Left Fuel Pump Parallel Light   

  ON (up to 10% NG)

Fuel Enrich Lamp   

  ON

Left ITT   

  MONITOR (660°C Maximum)

Left NG   

  52% Minimum

Left Oil Pressure Warning Light   

  OFF

Left Engine Starter Light   

  OFF

Bus Tie Warning Light   

  ON

Left Generator   

  ON

AC Transfer Switch   

  TRANSFER

Fuel Enrich Lamp   

  OFF

Left Boost Pump   

  OFF

Battery Charge Warning Light   

  OFF

AC Transfer Switch   

  NORMAL

Bus Tie   

  PRESS TO RESET

Right Generator   

  RESET

Right Generator   

  OFF

Right Boost Pump   

  ON

Right Fuel Condition Lever   

  TAXI

Right Fuel Pressure   

  CHECK (15 PSI Minimum)

Right Fuel Pressure Warning Light   

  OFF

Right Engine Selector   

  ON

Right Engine Starter   

  ON

Right Engine Oil Pressure   

  CHECKED FOR INDICATION

Right NG   

  STABLE (12% Minimum)

Right Fuel Condition Lever   

  LOW IDLE AND OBSERVE

Right Fuel Flow   

  CHECK

Right Fuel Pump Parallel Light   

  ON (up to 10% NG)

Fuel Enrich Lamp   

  ON

Right ITT   

  MONITOR (660°C Maximum)

Right NG   

  52% Minimum

Right Oil Pressure Warning Light   

  OFF

Right Engine Starter Light   

  OFF

Bus Tie Warning Light   

  ON

Right Generator   

  ON

AC Transfer Switch   

  TRANSFER

  Fuel Enrich Lamp   

  OFF

Right Boost Pump   

  OFF

Battery Charge Warning Light   

  OFF

AC Transfer Switch   

  NORMAL

Voltmeter Mode Switch   

  MAIN BUS

 

 

Starting Engine with Manual Starters (Battery Start)

 

Battery Switch   

  ON

Fasten Seat Belts Switch   

  ON

Voltmeter   

  CHECK (24 Volts Minimum)

Propeller Area   

  CLEAR

Air/Ground Switch   

  SET

Left Generator   

  RESET

Both Generators   

  OFF

Ignitions   

  NORMAL

Left and right IEC Computer   

  OFF

Low Pressure Fuel Valve   

  OPEN

Left Boost Pump   

  ON

Left Fuel Condition Lever   

  TAXI

Ignition 1 or 2   

  ENERGISE

Ignition Warning Light   

  ON

Fuel Enrich   

  PRESS ON

Left Fuel Pressure   

  CHECK (15 PSI Minimum)

Left Fuel Pressure Warning Light   

  OFF

Left Engine Starter   

  ON

Left Engine Oil Pressure   

  CHECKED FOR INDICATION

Left Fuel Pump Parallel Light   

  ON (up to 10% NG)

Left NG   

  STABLE (12% Minimum)

Ignition 1 or 2   

  IGNITE

Left Fuel Flow   

  CHECK

Left ITT   

  MONITOR (660°C Maximum)

Left NG   

  52% Minimum

Ignition 1 or 2   

  60%

Fuel Enrich   

  OFF

Left Oil Pressure Warning Light   

  OFF

Bus Tie Warning Light   

  ON

Left Generator   

  ON

AC Transfer Switch   

  TRANSFER

Left Boost Pump   

  OFF

Battery Charge Warning Light   

  OFF

AC Transfer Switch   

  NORMAL

Bus Tie   

  PRESS TO RESET

Ignition 1 or 2   

  NORMAL

Right Generator   

  RESET

Right Generator   

  OFF

Right Boost Pump   

  ON

Right Fuel Condition Lever   

  TAXI

Ignition 1 or 2   

  ENERGISE

Ignition Warning Light   

  ON

Fuel Enrich   

  PRESS ON

Right Fuel Pressure   

  CHECK (15 PSI Minimum)

Right Fuel Pressure Warning Light   

  OFF

Right Engine Oil Pressure   

  CHECKED FOR INDICATION

Right Fuel Pump Parallel Light   

  ON (up to 10% NG)

Right NG   

  STABLE (12% Minimum)

Ignition 1 or 2   

  IGNITE

Right Fuel Flow   

  CHECK

Right ITT   

  MONITOR (660°C Maximum)

Right NG   

  52% Minimum

Ignition 1 or 2   

  60%

Fuel Enrich   

  OFF

Right Oil Pressure Warning Light   

  OFF

Bus Tie Warning Light   

  ON

Right Generator   

  ON

AC Transfer Switch   

  TRANSFER

Right Boost Pump   

  OFF

Battery Charge Warning Light   

  OFF

AC Transfer Switch   

  NORMAL

Voltmeter Mode Switch   

  MAIN BUS

Ignition 1 or 2   

  NORMAL

 

 After Engine Start

 

Left LP Hydraulic Valve   

  OPEN

Right LP Hydraulic Valve   

  OPEN

Nonessential Avionics   

  ON

Navigation Light   

  ON

Rotary Beacon Lights   

  ON

Deice Controls   

  AS REQUIRED

Radios   

  AS REQUIRED

Trim Controls   

  SET

Flaps   

  SET

IEC Computers   

  ON

TTL Computers   

  AS REQUIRED

IEC and TTL Computer Annunciators   

  CHECK

Cabin Pressure Controller   

  AS REQUIRED

 

Taxi

 

Brakes